Skip to content
✦ Made with Docsie · generated from video

How to Backup a View SE Application in FactoryTalk

This guide explains how to backup a View SE application in FactoryTalk and how to restore it. You can use the Distributed Application Manager to back up and restore a Network Distributed application as a single compressed archive. You can also use the HMI Server Backup and Restore tool to back up and restore only an HMI Server file directory. Each application type can be backed up and restored with various tools.

FactoryTalk 31 steps 18 screenshots 2118 words Source video 7:40 Generated cost $2.80

Video: How to Backup and Restore a FactoryTalk View SE Network Distributed Application by Rockwell Automation (2017). All credit for the demonstration goes to the creator; watch the original on YouTube. The written guide below was generated from this video by Docsie. Creator? Request a change or removal.

This guide explains how to backup a View SE application in FactoryTalk and how to restore it. You can use the Distributed Application Manager to back up and restore a Network Distributed application as a single compressed archive. You can also use the HMI Server Backup and Restore tool to back up and restore only an HMI Server file directory. Each application type can be backed up and restored with various tools.

Prerequisites

Before you begin, make sure you have the following:

  • A FactoryTalk View Site Edition application of one of three types: Local Station, Network Station, or Network Distributed.
  • Access to the FactoryTalk View tools in the Windows Start menu, under Rockwell Software > FactoryTalk View > Tools.
  • For the HMI Server backup, a destination folder. The tool has no default backup location. This guide uses a folder named Backups that was created on the C: drive beforehand.

Identify the application type

Step 1: Review the three HMI application types

The FactoryTalk View Studio Application Type Selection window lists the types of HMI application that you can back up and restore. The View Site Edition (Network Distributed) option is highlighted.

  • Local Station
  • Network Station
  • Network Distributed
The FactoryTalk View Studio Application Type Selection window with the Network Distributed option highlighted, and a panel listing the Local Station, Network Station, and Network Distributed types
The FactoryTalk View Studio Application Type Selection window with the Network Distributed option highlighted, and a panel listing the Local Station, Network Station, and Network Distributed types

Open the backup tools

Step 2: Open the Windows Start menu

Open the Windows Start menu and browse to Rockwell Software > FactoryTalk View > Tools. The Tools folder lists the FactoryTalk utilities. The tool you need is named Application Manager.

The Windows Start menu open to the FactoryTalk View Tools folder, with Application Manager highlighted and a banner showing the navigation path
The Windows Start menu open to the FactoryTalk View Tools folder, with Application Manager highlighted and a banner showing the navigation path

Step 3: Select Application Manager

In the Tools folder, point to Application Manager. You use this tool to manage HMI application backups and restores.

The Start menu with Application Manager highlighted and the cursor pointing to it
The Start menu with Application Manager highlighted and the cursor pointing to it

Step 4: Launch Distributed Application Manager

To back up a Network Distributed application, you need the Distributed Application Manager tool instead. In the Tools folder, point to Distributed Application Manager and open it.

The Start menu with Distributed Application Manager highlighted and a banner explaining that it is required for Network Distributed backups
The Start menu with Distributed Application Manager highlighted and a banner explaining that it is required for Network Distributed backups

Step 5: Review the Distributed Application Manager home screen

The application window shows three tabs at the top: Home, Create a Backup, and Restore an Archive. The current user appears as WIN-E8H8THGOLV8\LABUSER. The main panel has two sections:

  • Create a backup (left): Describes three steps. Choose an application, review and customize, and finalize your backup.
  • Restore an archive (right): Gives instructions for restoring from a backup archive.

The Create Backup button is highlighted. An Activity Log at the bottom lists previous backup activities, including log file names, timestamps, and log file paths.

The Distributed Application Manager home screen with the Create Backup button highlighted, the backup and restore instructions, and the Activity Log
The Distributed Application Manager home screen with the Create Backup button highlighted, the backup and restore instructions, and the Activity Log

Back up a Network Distributed application

Step 6: Click Create Backup and review the application

Click Create Backup to begin. The application opens the Review and Customize step for the selected application, here NetworkDistributedDemoAplication.

The left panel shows a tree under "Network" with two applications: "InstantFizz" and "NetworkDistributedDemoAplication". The right panel lists the server details for the selected application:

  • Area: Data_Srv, HMI_Srv
  • Server Type: RSLinx Enterprise Server, HMI Server
  • Server Name: RSLinx Enterprise, NetworkDistributedDemoAplication
  • Host Machine: WIN-E8H8THGOLV8 for both servers

A Network Distributed application can be configured with different types of servers, and these servers could be hosted on different computers. In this demonstration, they are hosted on the same computer.

The Archive Name field is pre-filled with "NetworkDistributedDemoAplication". The Target Folder is set to C:\Users\Public\Documents\RSView Enterprise\SE\Archives.

Step 7: Review the server configuration

Before you start the backup, check the following:

  • All required servers (Data_Srv and HMI_Srv) are listed and hosted on the correct machine.
  • The Archive Name and Target Folder are correct.
  • If you want encryption, select "Encrypt the backup". It is not selected in this demonstration.

Step 8: Click Backup

Click the Backup button to start the backup process.

The Backup button being clicked, with the server configuration and archive details visible
The Backup button being clicked, with the server configuration and archive details visible

Step 9: Wait for the backup to complete

A modal window titled Backup Status: NetworkDistributedDemoAplication appears. When the backup finishes, the window shows a green checkmark and the message Backup Successful! It also shows Current Task: Backup Complete and a filled Overall Progress bar.

The log lists the backup steps:

  • Checking APB file
  • Checking disk space
  • Checking FactoryTalk Directory Server
  • Checking HMI Server connectivity
  • Prechecking complete
  • Getting HMI Information
  • Backing up FactoryTalk Directory
  • Compressing and downloading HMI application
  • Packaging configuration and log files

The window has two buttons: View Log and Close.

The Backup Status window showing Backup Successful, the filled progress bar, and the detailed log of backup steps
The Backup Status window showing Backup Successful, the filled progress bar, and the detailed log of backup steps

Step 10: Close the backup status window

Click Close. The application returns to the main "Choose Application" screen, where the left panel lists the available network applications.

Step 11: Verify the backup file in the Archives folder

The Archives folder is the default location for the single compressed backup file of an HMI application. It is in C:\Users\Public\Documents\RSView Enterprise\SE. Before the backup, this folder is empty.

Open Windows Explorer and go to C:\Users\Public\Documents\RSView Enterprise\SE\Archives. The folder now contains three files:

  • LocalStationDemoApplication.apa
  • NetworkDistributedDemoAplication.apb (highlighted)
  • NetworkStationDemoApplication.apa

The backup is a single compressed file in the Archives folder. The file extension for a Network Distributed application backup is .apb.

Windows Explorer showing the Archives folder with NetworkDistributedDemoAplication.apb highlighted and a note about the file extension
Windows Explorer showing the Archives folder with NetworkDistributedDemoAplication.apb highlighted and a note about the file extension

Back up a redundant Network Distributed application

Step 12: Begin the backup for a redundant application

In the Distributed Application Manager, select the Create a Backup tab. The left panel shows a network application named SodaFactory. The right panel lists three server areas:

  • Data_Area: RSLinx Enterprise Server, SERVER01
  • HMI_Area: HMI Server, SERVER01 (PRIMARY)
  • FTAETag_Area: Tag Alarm and Event Server, FTAETag_Server, SERVER01

The Archive Name is pre-filled with "SodaFactory". The Target Folder is C:\Users\Public\Documents\RSView Enterprise\SE\Archives. Click Backup to start.

Step 13: Note the redundancy configuration

When a drop-down selector is available for computer names under the Host Machine column, a Primary and Secondary for redundancy was configured in the Network Distributed architecture. In this example, the HMI_Area shows "SERVER01 (PRIMARY)" with a drop-down selector, which indicates redundancy.

Back up an HMI Server

Step 14: Launch the HMI Server Backup and Restore tool

Use the HMI Server Backup and Restore tool when you want to back up only an HMI Server file directory and its subdirectories, including all contained components. The backup is not a single compressed file. It preserves the original file structure. You can use the tool for any FactoryTalk View Site Edition application type.

In the Start menu, go to Rockwell Software > FactoryTalk View > Tools and select HMI Server Backup and Restore.

The Start menu open with the FactoryTalk tools listed and an information box describing the purpose of the HMI Server Backup and Restore tool
The Start menu open with the FactoryTalk tools listed and an information box describing the purpose of the HMI Server Backup and Restore tool

Step 15: Find the default HMI application folder

HMI application files are stored by default in a folder named HMI Projects. The path is C:\Users\Public\Documents\RSView Enterprise\SE\HMI Projects. The folder contains several subfolders and files, including demo applications and DLLs.

Step 16: Select the source HMI Server project

The Select Source HMI Project window opens. The tool automatically goes to the default folder C:\Documents and Settings\All Users\Documents\RSView Enterprise\SE\HMI Projects. The listed project folders include:

  • _bak
  • bin
  • InstantFizz_HMI
  • InstantFizz_SE
  • LocalStationDemoApplication
  • NetworkDistributedDemoAplication
  • NetworkStationDemoApplication

Choose a target HMI Server file directory and locate the file with the extension .sed.

Step 17: Choose the demonstration project

Open the NetworkDistributedDemoAplication folder. It contains several subfolders (EDS, Gfx, Global Objects, Images, and others) and the file NetworkDistributedDemoAplication.sed. Select that file.

Step 18: Specify the destination backup path

The tool has no default backup location. For this demonstration, a folder named Backups was created beforehand, and you select it as the destination.

The NetworkDistributedDemoAplication folder open, with an information box about selecting the Backups folder as the destination
The NetworkDistributedDemoAplication folder open, with an information box about selecting the Backups folder as the destination

The HMI Server Backup dialog then appears with these settings:

  • Source HMI server: C:\Documents and Settings\All Users\Documents\RSView Enterprise\SE\HMI Projects\NetworkDistributedDemoAplication
  • Destination backup path: C:\Backups
  • Exclude the datalog filesets: not selected

The Start Backup and Cancel buttons are visible. Click Start Backup to run the backup.

Step 19: Cancel the backup if needed

If you want to abort the operation, click Cancel in the HMI Server Backup dialog. No backup is started in this demonstration step.

Restore an archive

Step 20: Open the Distributed Application Manager and select an archive

  1. Launch the Distributed Application Manager.
  2. Select the Restore an Archive tab.
  3. In the left pane, expand the "Archives" folder.
  4. Select the archive file NetworkDistributedDemoAplication.apb.

The review and customization screen shows:

  • Application Version: 9.00.00
  • Date Created: 2016/10/04 13:11:43
  • Scope of Restore: "Restore application"
  • Restore selections for Data_Srv (RSLinx Enterprise Server, RSlinx Enterprise) and HMI_Srv (HMI Server, NetworkDistributedDemoAplication)
  • The same primary host for both servers: WIN-E8H8THGOLV8

A Network Distributed application can use different types of servers, which may be hosted on different computers. For this demonstration, both are hosted on the same computer.

The Distributed Application Manager with the archive selected and the server configuration, including a note about server hosting
The Distributed Application Manager with the archive selected and the server configuration, including a note about server hosting

Step 21: Click Restore

Click the Restore button at the bottom right of the window. A progress window titled "Restore Status: NetworkDistributedDemoAplication" appears. The current task is "Checking HMI Server connectivity." The log shows "Checking FactoryTalk Directory Server" and "Checking HMI Server connectivity." Wait for the progress bar to advance.

Step 22: Monitor the restore progress

The restore continues with these tasks:

  • Prechecking the environment
  • Unzipping the archive file
  • Restoring FactoryTalk Directory
  • Rehosting the RSLinx Enterprise server to the computer WIN-E8H8THGOLV8

The progress bar advances as each step completes.

The Restore Status window showing the detailed progress log and the rehosting step
The Restore Status window showing the detailed progress log and the rehosting step

Step 23: Confirm the restore completed

When the restore succeeds, the window shows "Restore Successful!" and the current task is "Restore Complete." The overall progress bar is full, and the log ends with "Restore Complete." Click Close to exit the restore status window.

The Restore Successful window with the completion log and the Close button highlighted
The Restore Successful window with the completion log and the Close button highlighted

Restore an archive with a redundant server configuration

Step 24: Select the redundant archive

In the Distributed Application Manager, stay on the Restore an Archive tab. In the left pane, select SodaFactory.apb under the "Archives" folder. The review and customize screen shows:

  • Application Version: 8.10.00
  • Date Created: 2016/03/31 15:21:00
  • Scope of Restore: "Restore application"
  • Restore selections for Data_Area (RSLinx Enterprise Server, RSlinx Enterprise), HMI_Area (HMI Server, SodaFactory), and FTAETag_Area (Tag Alarm and Event Server, FTAETag_Server)
  • A "Primary Host" and "Secondary Host" drop-down for each area, set to SERVER01 and SERVER02 respectively

The Restore button is at the bottom right.

Step 25: Understand the redundancy configuration

A drop-down selector for computer names under the Host Machine column means both Primary and Secondary hosts were configured for redundancy for that component. This setup allows for failover and increased reliability.

The screen highlighting the drop-down selectors for redundancy, with an explanatory note
The screen highlighting the drop-down selectors for redundancy, with an explanatory note

Restore an HMI Server

Step 26: Launch the HMI Server Backup and Restore tool

Open the Start menu and go to "All Programs" > "Rockwell Automation" > "FactoryTalk View" > "Tools". Select HMI Server Backup and Restore. The tool is highlighted in the menu, and a tooltip confirms the selection.

The tool can restore an HMI Server file directory and its subdirectories with all components. The restore overwrites an existing HMI Server project within a FactoryTalk View Site Edition application. The tool works regardless of the application type.

Step 27: Select the source HMI Server backup folder

In the Select Source HMI Server Project dialog, browse to your HMI Server backup. The tool does not have a default source location. For this demonstration, a folder named Backups was created on the C: drive, and an HMI Server project was backed up there. Select the Backups folder.

A file explorer window showing the Backups folder selected on the C: drive, with an information banner about the source location
A file explorer window showing the Backups folder selected on the C: drive, with an information banner about the source location

Step 28: Select the backup project file

Within the Backups folder, open the subfolder for your project, here NetworkDistributedDemoAplication. The folder contains several subfolders (EDS, Gfx, Global Objects, Images, and others) and the .sed file. Select NetworkDistributedDemoAplication.sed and click Open.

Step 29: Choose the destination restore path

The tool prompts you to select the destination for the restored HMI Server project. By default, it goes to the HMI Projects folder. In the folder selection dialog, expand and select the HMI Projects directory.

Within HMI Projects, select the directory that matches your backup project name, here NetworkDistributedDemoAplication. Click OK to confirm. The tooltip shows the folder name and creation date so you can verify your choice.

The folder selection dialog with the NetworkDistributedDemoAplication folder highlighted and an information banner
The folder selection dialog with the NetworkDistributedDemoAplication folder highlighted and an information banner

Step 30: Start the restore

Review the HMI Server Restore dialog. It shows:

  • Source HMI server path: C:\Backups\NetworkDistributedDemoAplication\NetworkDistributedDemoAplication.sed
  • Destination restore path: C:\Documents and Settings\All Users\Documents\RSView Enterprise\SE\HMI Projects\NetworkDistributedDemoAplication

Click Start Restore to begin restoring the project.

The HMI Server Restore dialog with the source and destination paths filled in, the Start Restore button highlighted, and an information banner
The HMI Server Restore dialog with the source and destination paths filled in, the Start Restore button highlighted, and an information banner

Step 31: Confirm the HMI Server restore completed

When the restore finishes, the tool returns to the main Select Operation window. A confirmation message appears at the bottom: HMI Server project restore complete. You can close the tool or continue with other operations.

The main tool window with the confirmation message "HMI Server project restore complete."
The main tool window with the confirmation message "HMI Server project restore complete."

Summary

You now know how to backup a View SE application in FactoryTalk and how to restore it. For a Network Distributed application, you use the Distributed Application Manager to create a single compressed archive with the .apb extension in the Archives folder. You then restore it from the Restore an Archive tab. For an HMI Server file directory, you use the HMI Server Backup and Restore tool. It backs up and restores the directory structure, using a source or destination folder that you choose.

Generation details: cost, quality tiers

Docsie billed 4,000 credits ($2.80) to analyze this 8-minute video at standard quality. The rewrite, template fill and Word/PDF exports were included. The same video at each quality tier:

QualityFrames sampledCreditsApprox. cost
Draftevery 16-30 s2,000$1.40
Standard (this guide)every 8-15 s4,000$2.80
Detailedevery 4-7 s8,000$5.60
Ultraevery 1-3 s16,000$11.20

Credits priced at $0.70 per 1,000; plans include a monthly allowance. Enterprise customers on on-premise or bring-your-own-model deployments run this on their own inference and pay no per-video credits.

Generated by Docsie Video-to-Docs on 2026-11-24 from a 7-minute video. Screenshots are frames from the source video and belong to their creator, Rockwell Automation, whose original is embedded above. If you own this video and want the guide removed or credited differently, contact us and we will act within one business day.

Turn your own training videos into guidesJoin teams that save hours, reduce documentation work and scale training with Docsie.
See Docsie in action. No commitment.

Ready to Transform Your Documentation?

Start creating professional documentation that your users will love