How to Backup a View SE Application in FactoryTalk
This guide explains how to backup a View SE application in FactoryTalk and how to restore it. You can use the Distributed Application Manager to back up and restore a Network Distributed application as a single compressed archive. You can also use the HMI Server Backup and Restore tool to back up and restore only an HMI Server file directory. Each application type can be backed up and restored with various tools.
Video: How to Backup and Restore a FactoryTalk View SE Network Distributed Application by Rockwell Automation (2017). All credit for the demonstration goes to the creator; watch the original on YouTube. The written guide below was generated from this video by Docsie. Creator? Request a change or removal.
This guide explains how to backup a View SE application in FactoryTalk and how to restore it. You can use the Distributed Application Manager to back up and restore a Network Distributed application as a single compressed archive. You can also use the HMI Server Backup and Restore tool to back up and restore only an HMI Server file directory. Each application type can be backed up and restored with various tools.
Prerequisites
Before you begin, make sure you have the following:
- A FactoryTalk View Site Edition application of one of three types: Local Station, Network Station, or Network Distributed.
- Access to the FactoryTalk View tools in the Windows Start menu, under Rockwell Software > FactoryTalk View > Tools.
- For the HMI Server backup, a destination folder. The tool has no default backup location. This guide uses a folder named Backups that was created on the C: drive beforehand.
Identify the application type
Step 1: Review the three HMI application types
The FactoryTalk View Studio Application Type Selection window lists the types of HMI application that you can back up and restore. The View Site Edition (Network Distributed) option is highlighted.
- Local Station
- Network Station
- Network Distributed

Open the backup tools
Step 2: Open the Windows Start menu
Open the Windows Start menu and browse to Rockwell Software > FactoryTalk View > Tools. The Tools folder lists the FactoryTalk utilities. The tool you need is named Application Manager.

Step 3: Select Application Manager
In the Tools folder, point to Application Manager. You use this tool to manage HMI application backups and restores.

Step 4: Launch Distributed Application Manager
To back up a Network Distributed application, you need the Distributed Application Manager tool instead. In the Tools folder, point to Distributed Application Manager and open it.

Step 5: Review the Distributed Application Manager home screen
The application window shows three tabs at the top: Home, Create a Backup, and Restore an Archive. The current user appears as WIN-E8H8THGOLV8\LABUSER. The main panel has two sections:
- Create a backup (left): Describes three steps. Choose an application, review and customize, and finalize your backup.
- Restore an archive (right): Gives instructions for restoring from a backup archive.
The Create Backup button is highlighted. An Activity Log at the bottom lists previous backup activities, including log file names, timestamps, and log file paths.

Back up a Network Distributed application
Step 6: Click Create Backup and review the application
Click Create Backup to begin. The application opens the Review and Customize step for the selected application, here NetworkDistributedDemoAplication.
The left panel shows a tree under "Network" with two applications: "InstantFizz" and "NetworkDistributedDemoAplication". The right panel lists the server details for the selected application:
- Area: Data_Srv, HMI_Srv
- Server Type: RSLinx Enterprise Server, HMI Server
- Server Name: RSLinx Enterprise, NetworkDistributedDemoAplication
- Host Machine: WIN-E8H8THGOLV8 for both servers
A Network Distributed application can be configured with different types of servers, and these servers could be hosted on different computers. In this demonstration, they are hosted on the same computer.
The Archive Name field is pre-filled with "NetworkDistributedDemoAplication". The Target Folder is set to C:\Users\Public\Documents\RSView Enterprise\SE\Archives.
Step 7: Review the server configuration
Before you start the backup, check the following:
- All required servers (Data_Srv and HMI_Srv) are listed and hosted on the correct machine.
- The Archive Name and Target Folder are correct.
- If you want encryption, select "Encrypt the backup". It is not selected in this demonstration.
Step 8: Click Backup
Click the Backup button to start the backup process.

Step 9: Wait for the backup to complete
A modal window titled Backup Status: NetworkDistributedDemoAplication appears. When the backup finishes, the window shows a green checkmark and the message Backup Successful! It also shows Current Task: Backup Complete and a filled Overall Progress bar.
The log lists the backup steps:
- Checking APB file
- Checking disk space
- Checking FactoryTalk Directory Server
- Checking HMI Server connectivity
- Prechecking complete
- Getting HMI Information
- Backing up FactoryTalk Directory
- Compressing and downloading HMI application
- Packaging configuration and log files
The window has two buttons: View Log and Close.

Step 10: Close the backup status window
Click Close. The application returns to the main "Choose Application" screen, where the left panel lists the available network applications.
Step 11: Verify the backup file in the Archives folder
The Archives folder is the default location for the single compressed backup file of an HMI application. It is in C:\Users\Public\Documents\RSView Enterprise\SE. Before the backup, this folder is empty.
Open Windows Explorer and go to C:\Users\Public\Documents\RSView Enterprise\SE\Archives. The folder now contains three files:
- LocalStationDemoApplication.apa
- NetworkDistributedDemoAplication.apb (highlighted)
- NetworkStationDemoApplication.apa
The backup is a single compressed file in the Archives folder. The file extension for a Network Distributed application backup is .apb.

Back up a redundant Network Distributed application
Step 12: Begin the backup for a redundant application
In the Distributed Application Manager, select the Create a Backup tab. The left panel shows a network application named SodaFactory. The right panel lists three server areas:
- Data_Area: RSLinx Enterprise Server, SERVER01
- HMI_Area: HMI Server, SERVER01 (PRIMARY)
- FTAETag_Area: Tag Alarm and Event Server, FTAETag_Server, SERVER01
The Archive Name is pre-filled with "SodaFactory". The Target Folder is C:\Users\Public\Documents\RSView Enterprise\SE\Archives. Click Backup to start.
Step 13: Note the redundancy configuration
When a drop-down selector is available for computer names under the Host Machine column, a Primary and Secondary for redundancy was configured in the Network Distributed architecture. In this example, the HMI_Area shows "SERVER01 (PRIMARY)" with a drop-down selector, which indicates redundancy.
Back up an HMI Server
Step 14: Launch the HMI Server Backup and Restore tool
Use the HMI Server Backup and Restore tool when you want to back up only an HMI Server file directory and its subdirectories, including all contained components. The backup is not a single compressed file. It preserves the original file structure. You can use the tool for any FactoryTalk View Site Edition application type.
In the Start menu, go to Rockwell Software > FactoryTalk View > Tools and select HMI Server Backup and Restore.

Step 15: Find the default HMI application folder
HMI application files are stored by default in a folder named HMI Projects. The path is C:\Users\Public\Documents\RSView Enterprise\SE\HMI Projects. The folder contains several subfolders and files, including demo applications and DLLs.
Step 16: Select the source HMI Server project
The Select Source HMI Project window opens. The tool automatically goes to the default folder C:\Documents and Settings\All Users\Documents\RSView Enterprise\SE\HMI Projects. The listed project folders include:
- _bak
- bin
- InstantFizz_HMI
- InstantFizz_SE
- LocalStationDemoApplication
- NetworkDistributedDemoAplication
- NetworkStationDemoApplication
Choose a target HMI Server file directory and locate the file with the extension .sed.
Step 17: Choose the demonstration project
Open the NetworkDistributedDemoAplication folder. It contains several subfolders (EDS, Gfx, Global Objects, Images, and others) and the file NetworkDistributedDemoAplication.sed. Select that file.
Step 18: Specify the destination backup path
The tool has no default backup location. For this demonstration, a folder named Backups was created beforehand, and you select it as the destination.

The HMI Server Backup dialog then appears with these settings:
- Source HMI server:
C:\Documents and Settings\All Users\Documents\RSView Enterprise\SE\HMI Projects\NetworkDistributedDemoAplication - Destination backup path:
C:\Backups - Exclude the datalog filesets: not selected
The Start Backup and Cancel buttons are visible. Click Start Backup to run the backup.
Step 19: Cancel the backup if needed
If you want to abort the operation, click Cancel in the HMI Server Backup dialog. No backup is started in this demonstration step.
Restore an archive
Step 20: Open the Distributed Application Manager and select an archive
- Launch the Distributed Application Manager.
- Select the Restore an Archive tab.
- In the left pane, expand the "Archives" folder.
- Select the archive file
NetworkDistributedDemoAplication.apb.
The review and customization screen shows:
- Application Version: 9.00.00
- Date Created: 2016/10/04 13:11:43
- Scope of Restore: "Restore application"
- Restore selections for
Data_Srv(RSLinx Enterprise Server, RSlinx Enterprise) andHMI_Srv(HMI Server, NetworkDistributedDemoAplication) - The same primary host for both servers:
WIN-E8H8THGOLV8
A Network Distributed application can use different types of servers, which may be hosted on different computers. For this demonstration, both are hosted on the same computer.

Step 21: Click Restore
Click the Restore button at the bottom right of the window. A progress window titled "Restore Status: NetworkDistributedDemoAplication" appears. The current task is "Checking HMI Server connectivity." The log shows "Checking FactoryTalk Directory Server" and "Checking HMI Server connectivity." Wait for the progress bar to advance.
Step 22: Monitor the restore progress
The restore continues with these tasks:
- Prechecking the environment
- Unzipping the archive file
- Restoring FactoryTalk Directory
- Rehosting the RSLinx Enterprise server to the computer
WIN-E8H8THGOLV8
The progress bar advances as each step completes.

Step 23: Confirm the restore completed
When the restore succeeds, the window shows "Restore Successful!" and the current task is "Restore Complete." The overall progress bar is full, and the log ends with "Restore Complete." Click Close to exit the restore status window.

Restore an archive with a redundant server configuration
Step 24: Select the redundant archive
In the Distributed Application Manager, stay on the Restore an Archive tab. In the left pane, select SodaFactory.apb under the "Archives" folder. The review and customize screen shows:
- Application Version: 8.10.00
- Date Created: 2016/03/31 15:21:00
- Scope of Restore: "Restore application"
- Restore selections for
Data_Area(RSLinx Enterprise Server, RSlinx Enterprise),HMI_Area(HMI Server, SodaFactory), andFTAETag_Area(Tag Alarm and Event Server, FTAETag_Server) - A "Primary Host" and "Secondary Host" drop-down for each area, set to
SERVER01andSERVER02respectively
The Restore button is at the bottom right.
Step 25: Understand the redundancy configuration
A drop-down selector for computer names under the Host Machine column means both Primary and Secondary hosts were configured for redundancy for that component. This setup allows for failover and increased reliability.

Restore an HMI Server
Step 26: Launch the HMI Server Backup and Restore tool
Open the Start menu and go to "All Programs" > "Rockwell Automation" > "FactoryTalk View" > "Tools". Select HMI Server Backup and Restore. The tool is highlighted in the menu, and a tooltip confirms the selection.
The tool can restore an HMI Server file directory and its subdirectories with all components. The restore overwrites an existing HMI Server project within a FactoryTalk View Site Edition application. The tool works regardless of the application type.
Step 27: Select the source HMI Server backup folder
In the Select Source HMI Server Project dialog, browse to your HMI Server backup. The tool does not have a default source location. For this demonstration, a folder named Backups was created on the C: drive, and an HMI Server project was backed up there. Select the Backups folder.

Step 28: Select the backup project file
Within the Backups folder, open the subfolder for your project, here NetworkDistributedDemoAplication. The folder contains several subfolders (EDS, Gfx, Global Objects, Images, and others) and the .sed file. Select NetworkDistributedDemoAplication.sed and click Open.
Step 29: Choose the destination restore path
The tool prompts you to select the destination for the restored HMI Server project. By default, it goes to the HMI Projects folder. In the folder selection dialog, expand and select the HMI Projects directory.
Within HMI Projects, select the directory that matches your backup project name, here NetworkDistributedDemoAplication. Click OK to confirm. The tooltip shows the folder name and creation date so you can verify your choice.

Step 30: Start the restore
Review the HMI Server Restore dialog. It shows:
- Source HMI server path:
C:\Backups\NetworkDistributedDemoAplication\NetworkDistributedDemoAplication.sed - Destination restore path:
C:\Documents and Settings\All Users\Documents\RSView Enterprise\SE\HMI Projects\NetworkDistributedDemoAplication
Click Start Restore to begin restoring the project.

Step 31: Confirm the HMI Server restore completed
When the restore finishes, the tool returns to the main Select Operation window. A confirmation message appears at the bottom: HMI Server project restore complete. You can close the tool or continue with other operations.

Summary
You now know how to backup a View SE application in FactoryTalk and how to restore it. For a Network Distributed application, you use the Distributed Application Manager to create a single compressed archive with the .apb extension in the Archives folder. You then restore it from the Restore an Archive tab. For an HMI Server file directory, you use the HMI Server Backup and Restore tool. It backs up and restores the directory structure, using a source or destination folder that you choose.
Generation details: cost, quality tiers
Docsie billed 4,000 credits ($2.80) to analyze this 8-minute video at standard quality. The rewrite, template fill and Word/PDF exports were included. The same video at each quality tier:
| Quality | Frames sampled | Credits | Approx. cost |
|---|---|---|---|
| Draft | every 16-30 s | 2,000 | $1.40 |
| Standard (this guide) | every 8-15 s | 4,000 | $2.80 |
| Detailed | every 4-7 s | 8,000 | $5.60 |
| Ultra | every 1-3 s | 16,000 | $11.20 |
Credits priced at $0.70 per 1,000; plans include a monthly allowance. Enterprise customers on on-premise or bring-your-own-model deployments run this on their own inference and pay no per-video credits.
Generated by Docsie Video-to-Docs on 2026-11-24 from a 7-minute video. Screenshots are frames from the source video and belong to their creator, Rockwell Automation, whose original is embedded above. If you own this video and want the guide removed or credited differently, contact us and we will act within one business day.