How to Upload an HMI Program in TIA Portal
If you want to know how to upload an HMI program in TIA Portal from a connected Siemens panel, this guide covers the workflow. You find the HMI on the network, open the Create backup dialog, and use SIMATIC ProSave to save a complete backup of the panel to a file on your computer. The example uses a TP700 Comfort panel.
Video: How to backup (upload) Siemens HMI in TIA portal by PLC Instru Short Tutorials PIST (2021). All credit for the demonstration goes to the creator; watch the original on YouTube. The written guide below was generated from this video by Docsie. Creator? Request a change or removal.
If you want to know how to upload an HMI program in TIA Portal from a connected Siemens panel, this guide covers the workflow. You find the HMI on the network, open the Create backup dialog, and use SIMATIC ProSave to save a complete backup of the panel to a file on your computer. The example uses a TP700 Comfort panel.
Prerequisites
- TIA Portal is open with your project loaded. The project tree shows devices such as "PLC_1 [CPU 312]" and "HMI_1 [TP700 Comfort]".
- Your computer has a network adapter you can select under PG/PC interface. The example uses "PN/IE" with "Realtek USB Gbe Family Controller".
- You have a folder where you can save the backup file.
Open the TIA Portal project
Make sure TIA Portal is open with your project loaded. The project tree on the left lists your devices, including "PLC_1 [CPU 312]" and "HMI_1 [TP700 Comfort]".
Open the accessible devices dialog
- In the project tree, go to the Online access section.
- Under PG/PC interface, select the appropriate network adapter, for example "PN/IE" and "Realtek USB Gbe Family Controller".
The Accessible devices in target subnet area is empty at first, and the Flash LED option is visible but not active.

Scan for accessible devices
Click Refresh to scan the network. The device "hmi_1" appears in the list with these details:
- Device type: SIMATIC-HMI
- Type: PN/IE
- Address: 192.168.0.2
- MAC address: 00-1B-1B-66-50-9D
The status area shows "Found accessible device hmi_1 [192.168.0.2]", "Scan completed: 1 devices found.", and "Retrieving device information...".

Select the detected device
- Highlight "hmi_1" in the device list.
- Confirm that the device details match your target HMI.
- Click Show to proceed.

Open the Create backup dialog
The Create backup window opens and lists the configured access nodes for "HMI_1":
- TP700 Comfort (Ethernet, 192.168.0.2)
- PROFINET Interface (PN/IE, 192.168.0.2)
- MPI/DP Interface (MPI, 1)
Configure the connection as follows:
- Set Type of the PG/PC interface to "Ethernet".
- Set PG/PC interface to "Ethernet".
- Under Address or name of target device, select "Configured IP Address" (192.168.0.2).
The status area confirms "Connection established to the device with address 192.168.0.2." and "Scan and information retrieval completed."

Change the PG/PC interface (optional)
If you need a different interface, open the PG/PC interface dropdown and choose from the available options:
- PN/IE
- TeleService
- S7USB
- Ethernet (selected in this example)

Use a different IP address (optional)
If required, select Use other IP and enter the IP address, which is 192.168.0.2 in this example. The status area updates as the connection attempt runs. Confirm that it reads "Connection established to the device with address 192.168.0.2."

Choose the backup file location
If prompted, use the file browser to select or create a folder for the backup.
- In this example, create a folder named "hmi bkp" on Local Disk (D:).
- Enter the file name "Temp.brf".
- Click Open.

Configure and start the backup in SIMATIC ProSave
The "SIMATIC ProSave V16.0.0.1 [Backup]" dialog appears.
- Set Data type to "Complete backup with licenses".
- In the Save as field, enter the backup file path, for example
D:\NEW\PLC\yoo pune\hmi bkp\Temp.brf. - Confirm that the listed device is "TP700_Comfort" via Ethernet.
- Check that the status area reads "Complete backup with licenses".
- Click Start backup.

Establish the connection
A progress window appears with the message "Establishing connection to device" and an image of two computers connected by a cable. Wait for the connection to be established and the backup to begin.

Monitor the backup progress
Watch the Progress window in SIMATIC ProSave V16.0.0.1. It shows:
- The status message "Creating the backup."
- Two computer icons connected by a cable, representing the data transfer.
- A blue progress bar that fills as the backup proceeds.
- A Cancel button, in case you need to stop the process.
Do not close the window or interrupt the process.

Verify that the backup completed
When the backup finishes, the Progress window closes automatically. The main SIMATIC ProSave window then shows:
- Data type: "Complete backup with licenses"
- Save as:
D:\hmi bkp\Temp.brf - Device: "TP700_Comfort" (Ethernet)
- Status message: "The backup was created successfully!"
The Start backup button is enabled again. Confirm that the status message indicates success before you close the application.

Close SIMATIC ProSave
Once you have confirmed the backup, close the SIMATIC ProSave window. The TIA Portal main interface stays open and shows the project tree and device overview.
Summary
You have created and verified a complete backup of your Siemens HMI (TP700 Comfort) using TIA Portal and SIMATIC ProSave. Store the backup file, Temp.brf, securely for future restoration or archival purposes.
What's next
- Keep the
Temp.brffile in a safe location for restoration or archiving. - Repeat the procedure whenever you want a new backup of the panel.
Generation details: cost, quality tiers
Docsie billed 1,500 credits ($1.05) to analyze this 3-minute video at standard quality. The rewrite, template fill and Word/PDF exports were included. The same video at each quality tier:
| Quality | Frames sampled | Credits | Approx. cost |
|---|---|---|---|
| Draft | every 16-30 s | 750 | $0.52 |
| Standard (this guide) | every 8-15 s | 1,500 | $1.05 |
| Detailed | every 4-7 s | 3,000 | $2.10 |
| Ultra | every 1-3 s | 6,000 | $4.20 |
Credits priced at $0.70 per 1,000; plans include a monthly allowance. Enterprise customers on on-premise or bring-your-own-model deployments run this on their own inference and pay no per-video credits.
Generated by Docsie Video-to-Docs on 2026-11-25 from a 2-minute video. Screenshots are frames from the source video and belong to their creator, PLC Instru Short Tutorials PIST, whose original is embedded above. If you own this video and want the guide removed or credited differently, contact us and we will act within one business day.