How to Connect to a PLC in TIA Portal
This guide shows you how to connect to a PLC in TIA Portal from your PC over an Ethernet cable. You create a project, add and detect your Siemens PLC, and establish the connection. You then configure the PLC security settings, compile the project, download it to the PLC, and check the status indicators.
Video: How to connect your PC to Siemens PLC using TIA Portal and Ethernet Cable by SparkLearning (2025). All credit for the demonstration goes to the creator; watch the original on YouTube. The written guide below was generated from this video by Docsie. Creator? Request a change or removal.
This guide shows you how to connect to a PLC in TIA Portal from your PC over an Ethernet cable. You create a project, add and detect your Siemens PLC, and establish the connection. You then configure the PLC security settings, compile the project, download it to the PLC, and check the status indicators.
Prerequisites
Before you start, make sure you have:
- A PC with Siemens TIA Portal installed
- A Siemens PLC
- An Ethernet cable to connect your PC to the PLC
Create a new project
Open TIA Portal
Launch the Siemens TIA Portal software on your PC. Wait for the start screen to load. It shows options such as Open existing project and Create new project, along with a list of recently used projects.

Create a new project
Click Create new project in the left sidebar. An input field for the project details appears at the top of the window.
Enter a name for your project. For example, type Spark One. Then click Create.

Open the project view
If prompted after the project is created, click Open the project view. The main TIA Portal interface appears, with the project tree on the left side.

Add and detect your PLC
Add a new device
In the project tree, right-click your project name (for example, SPARK1) and select Add new device. The Add new device dialog opens and shows device categories such as Controllers, HMI, and PC systems.
Select the PLC model
Under Controllers, expand the list and select the specific PLC you are using. In this example, expand SIMATIC ET200 CPU.
If you are unsure of the exact model, select Unspecified ET 200SP CPU. This lets TIA Portal detect the actual PLC automatically.

Connect the Ethernet cable
Physically connect your PC to the PLC using an Ethernet cable.
Start hardware detection
Click OK or Add to add the unspecified PLC to your project. The device configuration view opens and shows a warning that the device is not specified.
Click the detect link or button to start the hardware detection process.
Search for the PLC
In the hardware detection dialog, select the appropriate PG/PC interface (for example, Intel(R) Ethernet Controller). Click Start search to scan for connected devices.
When the scan completes, select your PLC from the list. In this example, the entry is Device: plc_1, Device type: CPU 15125P F-1 PN, Address: 192.168.0.3.

Connect to the PLC
Click Detect to confirm the device selection. If a security warning appears (for example, "plc_1 might not be a trustworthy device"), review the certificate information if necessary. Then click Connect.
Wait a few seconds for the connection process to complete. The PLC is now connected and ready for further configuration or programming.

Configure PLC security settings
Deactivate protection of confidential PLC data
In the PLC security settings dialog, select Protection of confidential PLC data. For learning purposes, make sure Protection of confidential PLC configuration data deactivated is selected.
Leave the password fields empty and do not set up a password. Click Next.

Remove secure internet HMI (if prompted)
If you are prompted about secure internet HMI, remove this option for learning purposes. Click Next to continue.
Set the access level without a password
In the PLC access protection section, open the Access level without password dropdown menu. Select Full access incl. fail-safe (no protection).
This setting gives all users full access to operations, including safety-related project data, without password protection. Click Finish to apply the settings.

Compile and download the project
Compile the project
After you finish the security configuration, compile your project to check for errors or warnings. In the main TIA Portal interface, review the results in the Compile tab at the bottom.
Make sure the message reads "Compiling finished (errors: 0; warnings: 1)" or similar. A single warning is generally not critical for learning purposes.

Start the download to the PLC
Click the Download to device button (the downward arrow icon) in the toolbar to start downloading your compiled project to the PLC. Wait a few seconds for the process to start.
If prompted, search for the PLC device again using the same procedure as in step 8.

Check the load preview
In the Load preview dialog, review the checklist before you load:
- Make sure the target PLC is correct (for example, PLC_1).
- Review any protection or warning messages.
- Confirm actions such as Stop modules, Delete and replace system data in target, and Download software to device.
Click Load to download the project to the PLC.

Wait for loading to complete
Wait for the loading process to finish. The new project overwrites any previous program on the PLC.
Check the status in the Messages or Info tab at the bottom of the screen. A message such as "Loading completed (errors: 0; warnings: 0/1)" indicates a successful download.

Verify the connection status
Check the project tree status indicators
Look at the project tree on the left side of the TIA Portal interface. Make sure all modules and devices display a green checkmark icon.
Green checkmarks indicate that your program is correct and all components are functioning as expected.

Interpret status colors
A color other than green, such as yellow or amber, on the project tree or device overview signals a problem. These indicators may point to issues with your PLC, your computer, or the connection between them.
To investigate, review the warnings or errors in the Details view or the Messages tab at the bottom of the screen.

Summary
You now know how to connect to a PLC in TIA Portal. You created a project, added and detected a Siemens PLC over Ethernet, and connected to it. You then configured the security settings for learning purposes, compiled the project, and downloaded it to the PLC. Finally, you confirmed the result with the green status indicators in the project tree.
Generation details: cost, quality tiers
Docsie billed 2,000 credits ($1.40) to analyze this 4-minute video at standard quality. The rewrite, template fill and Word/PDF exports were included. The same video at each quality tier:
| Quality | Frames sampled | Credits | Approx. cost |
|---|---|---|---|
| Draft | every 16-30 s | 1,000 | $0.70 |
| Standard (this guide) | every 8-15 s | 2,000 | $1.40 |
| Detailed | every 4-7 s | 4,000 | $2.80 |
| Ultra | every 1-3 s | 8,000 | $5.60 |
Credits priced at $0.70 per 1,000; plans include a monthly allowance. Enterprise customers on on-premise or bring-your-own-model deployments run this on their own inference and pay no per-video credits.
Generated by Docsie Video-to-Docs on 2026-11-24 from a 3-minute video. Screenshots are frames from the source video and belong to their creator, SparkLearning , whose original is embedded above. If you own this video and want the guide removed or credited differently, contact us and we will act within one business day.